JPL Technical Report Server

High-resolution displacement sensor using SQUID array amplifier

Show simple item record

dc.contributor.author Chui, T. en_US
dc.contributor.author Barmatz, M. en_US
dc.contributor.author Penanen, K. en_US
dc.date.accessioned 2004-09-16T23:53:07Z
dc.date.available 2004-09-16T23:53:07Z
dc.date.issued 2003-09-18 en_US
dc.identifier.citation Space Cryogenics Workshop 2003 en_US
dc.identifier.citation AK, USA en_US
dc.identifier.clearanceno 03-2443 en_US
dc.identifier.uri http://hdl.handle.net/2014/7887
dc.description.abstract We describe the design and operation principle of a new displacement sensor with a substantial improvement in resolution over what is currently possible. en_US
dc.format.extent 3202656 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.subject.other SQUID amplifier displacement sensor en_US
dc.title High-resolution displacement sensor using SQUID array amplifier en_US