JPL Technical Report Server

Cryocooler load increase due to external contamination of low-epsilon cyrogenic surfaces

Show simple item record

dc.contributor.author Ross, R. G. en_US
dc.date.accessioned 2004-09-17T06:02:06Z
dc.date.available 2004-09-17T06:02:06Z
dc.date.issued 2002-06-18 en_US
dc.identifier.citation 12th International Cryocooler Conference en_US
dc.identifier.citation Cambridge, MA, USA en_US
dc.identifier.clearanceno 02-1392 en_US
dc.identifier.uri http://hdl.handle.net/2014/8842
dc.description.abstract This paper attempts to compile available flight data on contamination effects experienced during multi-year space missions and ground tests to date as a help to those designing and conducting future long-life missions with cryocoolers. en_US
dc.format.extent 2524046 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.subject.other cryocooler load increase en_US
dc.title Cryocooler load increase due to external contamination of low-epsilon cyrogenic surfaces en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record