Abstract:
The trajectory required for the Cassini spacecraft to reach Saturn will subject the spacecraft to a 0.61 AU temperature environment at perihelion. Temperatures on some sunlit blanket surfaces at 0.61 AU can reach levels that are beyond the service capability of the conventional Mylar/Dacron net MLI. The majority of the blanket surfaces, however, will experience temperatures with an upper bound of 250° C. The maximum allowable temperature for Mylar/Dacron net is determined to be 220°C. Kapton can withstand temperatures in excess of 400° C; however, the high cost of embossed Kapton relative to Mylar/Dacron net requires a baseline design which includes a standard layup and a high-temperature layup. The high-temperature layup is utilized at a limited number of locations, while at least 90% of the blankets are of the standard layup. The verification of both layups' capability to meet all temperature requirements has been accomplished by a comprehensive test program which addressed their high-temperature survivability, effective emittance, and optical and electrical properties. This paper focuses on the high-temperature exposure tests which helped define the hybrid standard layup, and which demonstrated the adequacy of both layups in withstanding their respective thermal environments.