JPL Technical Report Server

Microwave Transmission Technique for Accurate Impedance Characterization of Superconductive Bolometric Mixers

Show simple item record

dc.contributor.advisor Karasik, B. S.
dc.contributor.author McGrath, W. R. en_US
dc.date.accessioned 2004-09-27T17:11:24Z
dc.date.available 2004-09-27T17:11:24Z
dc.date.issued 1997-10-14 en_US
dc.identifier.citation USA en_US
dc.identifier.clearanceno 97-1293 en_US
dc.identifier.uri http://hdl.handle.net/2014/22766
dc.description.abstract The impedance of the supconducting hot-electron bolometer mixer was measured in the range 0.2-4 GHz. A special technique relying on determination of S21 transmission parameter of the device was used. Many advantages of the techinque (wide frequency range, in sity calibration, low tes power, accuracy) are demonstrated. The estimate of the mixer bandwidth from the impedance data using the mixer theory is in good agreement with the results ofthe direct bandwidth measurements. en_US
dc.format.extent 229915 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.subject.other hot-electron bolometer mixer transmission en_US
dc.title Microwave Transmission Technique for Accurate Impedance Characterization of Superconductive Bolometric Mixers en_US