JPL Technical Report Server

Experimental Line Parameters of the Oxygen A-Band at 760 nanm

Show simple item record

dc.contributor.author Brown, L. en_US
dc.contributor.author Plymate, C. en_US
dc.date.accessioned 2004-09-24T16:00:32Z
dc.date.available 2004-09-24T16:00:32Z
dc.date.issued 1999-06 en_US
dc.identifier.citation Journal of Molecular Spectroscopy en_US
dc.identifier.citation USA en_US
dc.identifier.clearanceno 99-1008 en_US
dc.identifier.uri http://hdl.handle.net/2014/17586
dc.description.abstract To support atmospheric remote sensing applications, line positions, intensities, self- and nitrogen-broadened line widths and their temperature dependence and pressure-induced frequency shift at room temperature were measured up to J' and N' = 22 for the oxygen A-band at 13122 cm-1. en_US
dc.format.extent 1663224 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.subject.other oxygen line parameters A-band intensities pressure broadening calibration standards high resolution spectroscopy en_US